Loading...
HomeMy WebLinkAboutRESOLUTION NO. 2020-99 RESOLUTION NO. 2020-99 RESOLUTION TO APPROVE CHANGE ORDER NO. 4 FROM KLEIMAN CONSTRUCTION FOR THE 2020 PUMP HOUSE & SITE IMPROVEMENTS PROJECT WHEREAS, the City Council of Fairfax, Iowa has contracted with Kleiman Construction for the 2020 Pump House & Site Improvements project; and WHEREAS,Hall &Hall Engineers has recommended approval of Change Order#4 as described below. Add 12" Gate Valve to Distribution Main. Original Contract Amount: $2,278,183.54 C.O.#1 (Previously Approved) $4,606.20 C.O.#2 (Previously Approved) $3,284.27 C.O.#3(Previously Approved) $2,505.31 C.O. #4 $2.850.83 Revised Contract Amount: $2,291,430.15 NOW,THEREFORE,BE IT RESOLVED,by the City Council of the City of Fairfax, Iowa, to approve Change Order No. 4 from Kleiman Construction for the 2020 Pump House & Site Improvements project for an additional $2,850.83 making the contract amount $2,291,430.15. BE IT FURTHER RESOLVED, by the Fairfax City Council of the City of Fairfax, Iowa, that the Mayor and City Clerk/Treasurer are hereby authorized and directed to execute said resolution. Passed and approved this 10"' day of November, 2020. AYES: Otto, Daly, Pacha, Volk, and Wainwright NAYS: None Burnell G. Frieden, Mayor ATTEST: , Y C nthia Stimson, City Clerk/Treasurer °a HALL & HALL ENGINEERS, INC. CHANGE ORDER NO. 4 PROJECT: 2020 Pump House&Site Improvements DATE: November 5,2020 CONTRACTOR: Kleiman Construction ORIGINAL CONTRACT AMOUNT: $2,278,183.54 CONTRACT COMPLETION DATE: April 30,2021 ITEM#1: Add 12"Gate Valve to Distribution Main The 12"distribution main entering the pump house did not originally contain a valve in close proximity to the pump house. If any of the process piping inside the pump house would require future maintenance,the 12" distribution main would have to be shut off at the nearest valve currently located 85 feet away from the pump house. Shutting the 12"distribution main off at the valve 85 feet away would result in a separate 4"main being shut off as well. To avoid shutting off the 4"main while the 12"distribution main is shut off,an additional valve is required closer to the pump house. This additional 12"gate valve will be installed inside the pump house immediately after the point of entry of the distribution main. The attached Change Order Request submitted by the Contractor provides the price increase for furnishing and installing an additional 12"gate valve and the resulting pipe modifications required to fit the valve. The total Change Order 4 amount is$2,850.83. There will be no additional working days granted for these work changes. Original Contract Amount: $2,278,183.54 C.O.#1 (Previously Approved) $4,606.20 C.O.#2(Previously Approved) $3,284.27 C.O.#3(Previously Approved) $2,505.31 C.O.#4 $2.850.83 Revised Contract Amount: $2,291,430.15 Hall & Hall Engineers, Inc. City cyf airfax, Iowa Title: Pro4ect Engineer Title: Date: 11/5/20 Date: /�__ e '?-- C) CIVIL ENGINEERING"LAND SLIRVf_=YING'LAND DEVl=1_.OPMEN j PLANNING'LANDSCAPE.ARCHII-ECI URE 1860 Boyson Road'Hiawatha,IA 52233"Ph:3'19.362,9548'FAX:319.:362.7595 K.LEIMAN CONSTRUCTION INC. 6205 LOCUST RD.S.W, CEDAR RAPIDS,IA 52404 DATE: 10.6.2020 CHANGE ORDER REQUEST NO. 08 Omler. City of Fairfax PROJECT: Pump House and Srie Improvements 300 800'Street Court City of Fairfax Fairfax IA 52228 690 Wifliams Blvd. Faiffax IA 52228 AT N: Ion I arson ion:a4tallens.com PROJI C t XO: 4004 W CON _TRACT DATE 4—6.202-0-- A .2020w__A CHANGE 11"111E SCOPE OF WORK ANUORSPECIFICATIONS IS INDICAUD DELOW "rFIE OiVKER'S PRO."fM'RESPONSE IS REQUES'rE[) 1. Description of Change: COR#08: ITC#7 12"Gate Valve Mellen&Associates(See Attached Quotation)........................................................................ S 2,206.00 Bowker Mechanical(See Attached Email)........................................................................... S 360.00 SUBTOTAL S 2,566.00 10%SUBCONTRACTORS MARK UP S 256.60 SUBTOTAL S 2,822.60 l%BOND PREMR}M S 28.23 TOTAL CHANGE ORDER#0/ S� 2,8511.83 2. It is requested that the completion date be( -------X- _- )unchanged( }extended by calendar days. 3. Basis of Payment: a. ( X )ADD( )I) DUCT{ )NO CHANGE S 21650.83 TOIFROM the Contract Price. It. Time and material per Contract c. As per unit prices in Contract d. Other basis: Lump sum _._.--_---------------___—_- 4. Additional Terms and Conditions: a, Quoted prices arc guaranteed for a period of 8 calendar days from submittal date. b. Separate requests for time extensions will be considered valid and acceptable if no response is received within 10 calendar days from date of submittal. Submitted By: �' �� �St�^ eu I,.IUeimatt,President .r Approved By: ,Ion l.'tion Hall&Nall Engineers,Inc. MELLEN& INC.ASSOCIATES, C3404 S.11th St, Council Blutfs IA 51501 QUOTATION#:2020-09-29-PL-1 QUOTATION DATE:September 29,2020 WALVES'ACTUATOIS'EQUIPMENT PREPAREORY;Paul Lewis MUNCIPAI"POVUK*PROCESS Ph:(712)322-9333 NEBRASKA'IOWA'KANSAS'MISSIIII Fax:(712)322-6557 paul@meileninc.com PROJECTNME: Fairfax, IA - 2020 Pump House & Site QUQTEOTO: ITC#7 TERMS: 100%Nei 30 Days f,0,8.;Factory TREIQHTTERMS:Prepay&Add Attn: Ph: Fax: E-Mail: [ND. Tag QDantnt Site f description et Nei NortbWBst Corner o/8011ding 1 ITC No.7 1 12" 112"Gate Valve Flanged NRS with hand wheel, AIS compliant $ 2,206 $ 2,206 TERMS 9 CONDITIONS 1.Price does not include mechanical joint accessories,valve boxes,special coatings,special tagging,tee operating wrenches,flange gaskets,bolts, installation services,test certifications,field start up services,special crating,extended warranties or packaging for export-unless otherwise noted. 2.State and local use taxes are not included.Tax exempt certificates must be provided if the project is determined to be tax exempt. 3.This quotation reflects our policy of sourcing raw materiafs in the most cost effective manner.Any requirements for specific U.S.content may require a revised quotation.Equipment may not be compliant with special ARRA,SRF or"Buy American"funding conditions, unless quoted as such. 4.A maximum of 8 printed Submittal&O&M will be provided on double-sided prints in a loose,unbound,and untabbed format.Electronic copies will be available via a-mail as an Adobe Acrobat PDF fife.Any requirements for special formatting,including but not limited to,binders,separation tabs, Color Prints,Single-Sided Prints,Compact Disc or USB Flash Drive will be subject to additional charges. 5.This quotation was prepared with limited specifications,and/or application data.Any subsequent changes to materials,coatings, features,actuation,accessories,or otherwise shall require a re-quotation. 6.This quotation is limited to the scope,supply&descriptions above.Please review all necessary valve/tag schedules,and installation drawings to ensure all items are included. 7.This quotation/order is subject to the manufacturers'acceptance,standard warranty and terms and conditions(available upon request). 8.This repair quote is an estimate only.Should the need for additional parts and repairs be discovered after repair work has begun or during testing,this quote will be adjusted to reflect the cost of additional repairs.You will be notified prior to the repair being accomplished. 9.Mellen&Associates will provide a Certificate of Insurance upon request but will not issue Additional Insured certificates.In addition we will not accept any terms that waive subrogation or include any non-contributory contract language." 10.Automated valve packages,Field Service,and Start-Up may be invoiced separately. 11.Delivery quotes represent an estimate only,with all items quoted as"subject to prior sale". 12.Pricing will be held for 30 days. ADDITIONAL COMMENTS 1.Please reference quotation number 2020-09-29-PL-1 on all purchase orders&correspondence. 2.Purchase Orders resulting from this quotation shall be issued to"Mellen&Associates,Inc". 3.STARTUP SERVICES:If required,startup services will be billed at a rate of$125 per hour,including travel.A separate purchase order may be required. Steve Kleiman From: Alex Frey <afrey@bowkermechanical.com> Sent: Thursday, October 1, 2020 9:21 AM To: Steve Kleiman Subject: RE: Fairfax Pump House - ITC No.7 - Add 12" Gate Valve Steve, Please add$360 for this change. Thank you. From:Steve Kleiman<skleiman@kleimanconstruction.com> Sent:Wednesday,September 23, 2020 9:17 AM To:Sydney Puder<sdpuder@vessco.com>;Alex Frey<afrey@bowkermechanical.com> Subject: FW: Fairfax Pump House-ITC No. 7-Add 12" Gate Valve Sydney/Alex, Please get me pricing for this,thanks. From:Jon Larson<ion halleng.com> Sent:Tuesday, September 22, 2020 1:18 PM To:Steve Kleiman<skleiman@kleimanconstruction.com> Cc: Matthew Sattler<msattler @kleimanconstruction.corii>; Kevin Stensland<KStenslandCo)cityoffairfax.org>;Dave Schechinger<dschechinger v-k.net>;Shane Wicks<shane Kallen .com> Subject: Fairfax Pump House-ITC No. 7-Add 12"Gate Valve Steve, See attached ITC No. 7 regarding the addition of a gate valve to the 12" distribution pipe in the NW corner of the building. Please let me know if you have any questions. Thanks Jon Larson, P.E. Hall & Hall Engineers, Inc. i